How to solve the problem that the weighbridge is soaked in water in rainy days?

For our users in the south, due to the influence of the local seasonal climate, we will give you a storm if we don't agree with each other, making you "impossible to prevent". In addition, liquid immersion of the weighbridge is also one of the problems puzzling the majority of users. So, how should we properly handle this situation after it happens? Now let's explain the failures that will occur if the weighbridge product is soaked in water and the corresponding solutions.
Solution 1: First of all, we should give the product breakpoint at the first time, and then disassemble the sensors, junction boxes, weighing instruments and other electronic components to check one by one to see if there is water ingress. Anyone who knows the working principle of the weighbridge knows that the final weighing data is transmitted to the weighing instrument through the sensor. If there is water in the weighbridge, it must be cleaned before it is put into use, otherwise short circuit and unstable signal output will occur. We try to clean the accumulated water by air drying. After ensuring that the junction box is dry, power on it to check whether the weighing is normal. If the fault still occurs, replace the junction box with a new one.
Treatment method 2: If water enters the weighing sensor of the weighbridge, the angle difference between the four corners is generally too large. If the weighbridge is soaked in water for a long time, the circuit inside the weighing sensor will be damaged, which will lead to inaccurate weighing data or data jumping when the product is working. Therefore, we must check whether the state of the weighing sensor is normal with the universal detector before using it. If any problem is found, the sensor needs to be replaced!
Well, the above is a small editor to explain the failures and corresponding solutions that will occur if the weighbridge product is soaked in water. I hope it will be helpful to you. You can leave a message or consult online if you have any questions about the weighbridge.

相关新闻

About us     |     Honor     |     News Center     |     Technical service     |     Feedback     |     Contact us 

Building material     |         Luqiao     |      Metallurgy     |      Petroleum     |       Traffic logistics    |       Other

Scale, platform scale business hotline: 0771-3159933  

Platform scale, electronic scale business hotline: 0771-3153889After service

telephone: 0771-3165266

Complaint telephone: 0771-3154958

Company address: No. 10, North inter South Road, Nanning.

Q Q: 1363900082
Mailbox:nngflz@163.com

Fax: 0771-3170520

Bus Line: Chaoyang Square can take No. 18; Langdong Station, Xixiangtang Station can take No. 76; Jinqiao Station can take No. 81; Jiangnan Station can take No. 207 and No. 81 to get off at Beijida intersection.

Copyright ©  Nanning Weighing Machine Factory